Nelsonville receives final structural condition assessment for The Mine Tavern, on the Public Square, with conclusions and recommendations

The Nelsonville Division of Fire has received the final structural condition assessment for The Mine Tavern, located at 14 Public Square. The structural condition assessment was conducted by Derwacter & Associates, LLC from Zanesville. The structural condition assessment has the following conclusions and recommendations,

Conclusions

Based on the observed conditions, it is the opinion of the undersigned structural engineer that the building represents an immediate and significant collapse hazard. The compromised north wall, unsupported floor and roof framing, and deteriorated east and west masonry walls create a high risk of progressive structural failure.

The structure is not safe for occupancy in any capacity. Continued access to the building presents an unacceptable risk to life safety.

Continued progressive failure could pose a risk to the adjacent buildings to the north and south, sidewalk, and street located to the west of the building.

Recommendations

The building should be immediately secured to prevent unauthorized entry.

Adjacent buildings, as well as the sidewalk and roadway along the west side of the structure, should be closed until the hazard is mitigated.

Immediate action should be taken to either shore and stabilize the structure or proceed with controlled demolition, with careful consideration given to the protection of adjacent structures.

The full assessment is attached and can also be downloaded at https://tinyurl.com/3j3f4ksu.

The East side of the Public Square remains closed and barricaded to all vehicle and pedestrian traffic from the Dew House to the end of Rhapsody restaurant until further notice. Please avoid this area and use an alternative route. Further updates will be released as information becomes available.